• Home
  • Practice Focus
    • Facial Plastic/Reconstructive
    • Head and Neck
    • Laryngology
    • Otology/Neurotology
    • Pediatric
    • Rhinology
    • Sleep Medicine
    • How I Do It
    • TRIO Best Practices
  • Business of Medicine
    • Health Policy
    • Legal Matters
    • Practice Management
    • Tech Talk
    • AI
  • Literature Reviews
    • Facial Plastic/Reconstructive
    • Head and Neck
    • Laryngology
    • Otology/Neurotology
    • Pediatric
    • Rhinology
    • Sleep Medicine
  • Career
    • Medical Education
    • Professional Development
    • Resident Focus
  • ENT Perspectives
    • ENT Expressions
    • Everyday Ethics
    • From TRIO
    • The Great Debate
    • Letter From the Editor
    • Rx: Wellness
    • The Voice
    • Viewpoint
  • TRIO Resources
    • Triological Society
    • The Laryngoscope
    • Laryngoscope Investigative Otolaryngology
    • TRIO Combined Sections Meetings
    • COSM
    • Related Otolaryngology Events
  • Search

Robotic Micromanipulator Can Strengthen Laryngeal Surgery Skills

by Amy Hamaker • June 8, 2015

  • Tweet
  • Click to email a link to a friend (Opens in new window) Email
Print-Friendly Version

Clinical Question

How well do experienced and novice participants perform using a prototype robotic micromanipulator controller (RMC) in a simulated, microlaryngeal operative setting?

You Might Also Like

  • A Look at Transoral Robotic Surgery with Synchronous Neck Dissection
  • Robotic Platform Can Assist Novice Microvascular Surgeons in Reducing Vibrations
  • Robotic Surgery Offers Advantages for Infratemporal Fossa
  • Experience with Robotic Thyroid Surgery in North American Patients
Explore This Issue
June 2015

Background: The majority of robotic surgical procedures involve explicit human operator direction and control. Over the last four decades, the coincident advances of robotic surgical technology, microlaryngeal surgical technique, CO2 laser laryngeal surgery, and computer-controlled surgical CO2 laser guidance have led to the development of the prototype (RMC).

Study design: Observational cross-sectional study of 22 recruited participants.

Setting: University of North Carolina Department of Otolaryngology, Chapel Hill.

Synopsis: Participants were presented with a preformed, curvilinear target path and were asked to guide the helium-neon (HeNe) target beam as close as possible to the center of the 4-mm-wide path for three consecutive repetitions. In addition, a predesigned path was transferred onto a block of extra firm tofu; participants were asked to trace the pattern in a consistent and continuous fashion. There was a moderate negative correlation between increasing previous laser surgical experience and error percentage, cumulative error, and performance repeatability in those using a manual micromanipulator (MMM). A statistically significantly lower error percentage was identified for surgeons with fewer than 50 previous laser cases. A similar significant difference in cumulative error was observed for surgeons with fewer than 10 previous laser surgical cases. A moderate negative correlation was observed between repetition error and level of previous laser experience. There was no statistical ablation consistency and there were no significant differences in error percentage, cumulative error, or repetition error difference across any subject variables. No correlation with improved performance was seen with the RMC device across laser experience. The RMC P/A mode trended toward less repetition error compared to human participants as a group. A statistically significant repetition error difference was observed between the RMC programmed (P/A) mode and participants with fewer than 100 cases of laser experience. Limitations include known shortcomings of the prototype RMC.

Bottom line: Experienced laser surgeons perform better than novice surgeons on accuracy and repeatability tasks using the MMM but roughly equivalently using the RMC. In P/A mode, the RMC performs equivalently or superior to experienced laser surgeons using the industry standard MMM for all measured parameters and delivers an ablation consistency nearly an order of magnitude better than human laser operators.

Citation: Buckmire RA, Wong YT, Deal AM. The application of robotics to microlaryngeal laser surgery. Laryngoscope. 2015;125:1393-1400.

Filed Under: Laryngology, Literature Reviews Tagged With: laryngeal, roboticsIssue: June 2015

You Might Also Like:

  • A Look at Transoral Robotic Surgery with Synchronous Neck Dissection
  • Robotic Platform Can Assist Novice Microvascular Surgeons in Reducing Vibrations
  • Robotic Surgery Offers Advantages for Infratemporal Fossa
  • Experience with Robotic Thyroid Surgery in North American Patients

The Triological SocietyENTtoday is a publication of The Triological Society.

Polls

Have you successfully navigated a mid-career change?

View Results

Loading ... Loading ...
  • Polls Archive

Top Articles for Residents

  • ENTtoday Welcomes Resident Editorial Board Members
  • Applications Open for Resident Members of ENTtoday Edit Board
  • How To Provide Helpful Feedback To Residents
  • Call for Resident Bowl Questions
  • New Standardized Otolaryngology Curriculum Launching July 1 Should Be Valuable Resource For Physicians Around The World
  • Popular this Week
  • Most Popular
  • Most Recent
    • The Dramatic Rise in Tongue Tie and Lip Tie Treatment

    • Changing Perspectives: Why ENT Surgeons Should Consider Nerve Reconstruction

    • Otolaryngologists Are Still Debating the Effectiveness of Tongue Tie Treatment

    • Rating Laryngopharyngeal Reflux Severity: How Do Two Common Instruments Compare?

    • Keeping Watch for Skin Cancers on the Head and Neck

    • The Dramatic Rise in Tongue Tie and Lip Tie Treatment

    • Rating Laryngopharyngeal Reflux Severity: How Do Two Common Instruments Compare?

    • Is Middle Ear Pressure Affected by Continuous Positive Airway Pressure Use?

    • Otolaryngologists Are Still Debating the Effectiveness of Tongue Tie Treatment

    • Complications for When Physicians Change a Maiden Name

    • ENTtoday Welcomes Resident Editorial Board Members
    • Journal Publishing Format Suggestion: A Greener Future for Medical Journals
    • Physician, Know Thyself! Tips for Navigating Mid-Career Transitions in Otolaryngology
    • PA Reform: Is the Administrative War of Attrition Ending?
    • How To: Anatomic-Based Technique for Sensing Lead Placement in Hypoglossal Stimulator Implantation

Follow Us

  • Contact Us
  • About Us
  • Advertise
  • The Triological Society
  • The Laryngoscope
  • Laryngoscope Investigative Otolaryngology
  • Privacy Policy
  • Terms of Use
  • Cookies

Wiley

Copyright © 2025 by John Wiley & Sons, Inc. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies. ISSN 1559-4939