• Home
  • Practice Focus
    • Facial Plastic/Reconstructive
    • Head and Neck
    • Laryngology
    • Otology/Neurotology
    • Pediatric
    • Rhinology
    • Sleep Medicine
    • How I Do It
    • TRIO Best Practices
  • Business of Medicine
    • Health Policy
    • Legal Matters
    • Practice Management
    • Tech Talk
    • AI
  • Literature Reviews
    • Facial Plastic/Reconstructive
    • Head and Neck
    • Laryngology
    • Otology/Neurotology
    • Pediatric
    • Rhinology
    • Sleep Medicine
  • Career
    • Medical Education
    • Professional Development
    • Resident Focus
  • ENT Perspectives
    • ENT Expressions
    • Everyday Ethics
    • From TRIO
    • The Great Debate
    • Letter From the Editor
    • Rx: Wellness
    • The Voice
    • Viewpoint
  • TRIO Resources
    • Triological Society
    • The Laryngoscope
    • Laryngoscope Investigative Otolaryngology
    • TRIO Combined Sections Meetings
    • COSM
    • Related Otolaryngology Events
  • Search

No Correlation Between IAC Diverticula Presence/Size and Degree of Hearing Loss

by Amy E. Hamaker • April 10, 2020

  • Tweet
  • Click to email a link to a friend (Opens in new window) Email
Print-Friendly Version

What is the relationship between hearing loss and internal auditory canal (IAC) diverticula, and are diverticula within or medial to the otic capsule?

Bottom line: IAC diverticula size does not correlate with hearing loss degree, and there is no statistically significant association between SNHL and IAC diverticulum presence.

You Might Also Like

  • Study Supports Correlation Between Hearing Loss and Dementia in Older Patients
  • Patient with Conductive Hearing Loss
  • Hearing Loss Associated with Higher Incidence of Dementia
  • What Defines Asymmetric Sensorineural Hearing Loss?
Explore This Issue
April 2020

Background: Authors previously highlighted the association between IAC diverticula (small, nonvascular, low-density outpouchings from the normal linear contour of the IAC wall) and hearing loss, which occurred in 91% of the patients with IAC diverticula and no signs of fenestral or retrofenestral otosclerosis. This prompted the question: Does an IAC diverticulum itself cause hearing loss?

Study design: Retrospective review of adult patients with radiologic evidence of an IAC diverticulum, no evidence of otosclerosis, and audiometric testing between January 2013 and January 2016.

Synopsis: In the control group of 160 patients and 320 temporal bones, nine patients had bilateral IAC diverticula; their mean age was 61. In those with hearing loss, the majority of audiograms displayed a sloping curve similar to presbycusis. Forty-three temporal bones with an IAC diverticulum without radiographic evidence of fenestral or retrofenestral otosclerosis showed a mean pure tone average (PTA) of 50, a mean air-bone gap of 9, and a mean word recognition score of 67. Of these temporal bones, four of 43 showed no hearing loss; 27 of 43 showed sensorineural hearing loss (SNHL); 12 of 43 showed mixed hearing loss; and none showed conductive hearing loss. The mean diverticulum length was 0.95 mm, the mean width at mouth was 1.30 mm, and the mean width at middle was 0.95 mm. Spearman’s rho failed to show a correlation between diverticula measurements and audiometric data. There was a statistically insignificant difference between unilateral and contralateral diverticulum patients. Limitations included sampling bias innate to a case series.

Citation: Muelleman TJ, Pippin K, Shew M, et al. The size of internal auditory canal diverticula is unrelated to degree of hearing loss. Laryngoscope. 2020;130:1011-1015.    

Filed Under: Literature Reviews, Otology/Neurotology Tagged With: hearing lossIssue: April 2020

You Might Also Like:

  • Study Supports Correlation Between Hearing Loss and Dementia in Older Patients
  • Patient with Conductive Hearing Loss
  • Hearing Loss Associated with Higher Incidence of Dementia
  • What Defines Asymmetric Sensorineural Hearing Loss?

The Triological SocietyENTtoday is a publication of The Triological Society.

Polls

Do you use AI-powered scribes for documentation?

View Results

Loading ... Loading ...
  • Polls Archive

Top Articles for Residents

  • Applications Open for Resident Members of ENTtoday Edit Board
  • How To Provide Helpful Feedback To Residents
  • Call for Resident Bowl Questions
  • New Standardized Otolaryngology Curriculum Launching July 1 Should Be Valuable Resource For Physicians Around The World
  • Do Training Programs Give Otolaryngology Residents the Necessary Tools to Do Productive Research?
  • Popular this Week
  • Most Popular
  • Most Recent
    • How to: Positioning for Middle Cranial Fossa Repair of Superior Semicircular Canal Dehiscence

    • The Dramatic Rise in Tongue Tie and Lip Tie Treatment

    • Rating Laryngopharyngeal Reflux Severity: How Do Two Common Instruments Compare?

    • Otolaryngologists Are Still Debating the Effectiveness of Tongue Tie Treatment

    • Endoscopic Ear Surgery: Advancements and Adoption Challenges 

    • The Dramatic Rise in Tongue Tie and Lip Tie Treatment

    • Rating Laryngopharyngeal Reflux Severity: How Do Two Common Instruments Compare?

    • Is Middle Ear Pressure Affected by Continuous Positive Airway Pressure Use?

    • Otolaryngologists Are Still Debating the Effectiveness of Tongue Tie Treatment

    • Complications for When Physicians Change a Maiden Name

    • The Importance of Time Away
    • Endoscopic Ear Surgery: Advancements and Adoption Challenges 
    • Reflections from a Past President of the Triological Society
    • ENT Surgeons Explore the Benefits and Challenges of AI-Powered Scribes: Revolutionizing Documentation in Healthcare
    • How To: Open Expansion Laryngoplasty for Combined Glottic and Subglottic Stenosis

Follow Us

  • Contact Us
  • About Us
  • Advertise
  • The Triological Society
  • The Laryngoscope
  • Laryngoscope Investigative Otolaryngology
  • Privacy Policy
  • Terms of Use
  • Cookies

Wiley

Copyright © 2025 by John Wiley & Sons, Inc. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies. ISSN 1559-4939